1. What is SDI?

At present, the best possible technology to effectively evaluate the colloid pollution in the inlet of RO/NF system is to measure the siltation density index (SDI, also known as pollution plugging index) of the inlet water, which is an important parameter that must be determined before the design of RO. During the operation of RO/NF, it must be measured regularly (for surface water measured 2-3 times a day). ASTM D4189-82 specifies the standard for this test. The inlet water regulation of the membrane system is that the value of SDI15 must be ≤5. The effective techniques to reduce SDI pretreatment include multi-media filter, ultrafiltration, microfiltration, etc. The ability of the above physical filtration to reduce the SDI value is sometimes enhanced by the addition of poly dielectric prior to filtration.

 

2. How do you remove silicon from water?

Silicon in water exists in two forms, active silicon (monomer silicon) and colloidal silicon (polysilicon) : Colloidal silicon has no ionic characteristics, but the scale is relatively large, colloidal silicon can be trapped by fine physical filtration processes, such as reverse osmosis, can also be reduced by coagulation technology, such as clarifiers, but those that rely on ion charge characteristics of separation technology, such as ion exchange resin and continuous electric deionization process (CDI), It has very limited effect on the removal of colloidal silicon.

The size of active silicon is much smaller than that of colloidal silicon, so most of the physical filtration technologies such as coagulation and clarification, filtration and air flotation are unable to remove active silicon. The processes that can effectively remove active silicon are reverse osmosis, ion exchange and continuous electric deionization.


3. What is the effect of chromium on RO film?

Some heavy metals such as chromium can catalyze the oxidation of chlorine and cause the irreversibility of the film to decay. This is because Cr6+ is less stable than Cr3+ in water. It seems that metal ions with high oxidation potential, the damage is even stronger. Therefore, chromium concentration should be reduced or at least Cr6+ should be reduced to Cr3+ in the pretreatment part.

 

4. What kind of pretreatment is required for RO systems?

The usual pretreatment system composition is as follows, coarse filter (~ 80 microns) to remove large particles, add sodium hypochlorite and other oxidants, and then through the multi-medium filter or clarifying pool for precision filtration, and then add sodium bisulfite reduction residual chlorine and other oxidants, and finally install the security filter before the high-pressure pump inlet. The security filter is used as the final insurance measure to prevent the damage of accidental large particles to the high-pressure pump impeller and membrane elements. Water sources containing more suspended particles usually need a higher degree of pretreatment to meet the requirements of the water intake. For water with high hardness content, it is recommended to soften or add acid and scale inhibitor. For water with high microbial and organic content, activated carbon or anti-pollution membrane elements are also needed.

 

5. How do you know if the membrane is contaminated?

Common symptoms of contamination are: at standard pressure, water production decreases in order to achieve standard water production, the operating pressure must be increased v, the pressure drop between inlet and concentrated water increases v, the weight of the membrane element increases v, film removal rate significantly changes (increases or decreases). When the element is removed from the pressure vessel, the water is poured on the inlet side of the raised membrane element. The water cannot flow through the membrane element and only overflows from the end face (indicating that the inlet channel is completely blocked).