We use our innovative technology to continue to provide customers with a more satisfactory complete set of 8040 High Flux RO Membrane ELements, fixed branch pipe length, Tubing High Pressure GRE Pipe solutions. Relying on a global marketing and operation service network, and a professional overall solution service team built for key markets, our products have footprints in many countries around the world. In the development process, the company always takes product quality as the goal, and continuously devotes itself to product research and development. We encourage employees to actively participate in annual outdoor training to enhance corporate team cohesiveness. To produce first-class products and provide first-class services is our permanent commitment.
Product Features
High rejection while High flux.
Applications
Desalination of seawater and brackish water, Concentration and Recycling of high salt concentration.
Technical Parameters
Model | Permeate Flow GPD (m3/d) | Active Membrane Area ft2 (m2) | Stabilized Salt Rejection | Feed Spacer mil (mm) | Test Conditions |
MW-HF8040-375 | 9000(34.1) | 375(34.9) | 99.5% | 28(0.7) | 225psi/2000ppmNaCl |
MW-HF8040-400 | 10200(38.6) | 400(37.2) | 99.5% | 28(0.7) | 225psi/2000ppmNaCl |
MW-HF8040-440 | 12000(45.4) | 440(38.1) | 99.5% | 28(0.7) | 225psi/2000ppmNaCl |
1.All performance data are collected at 25℃ (77℉), PH7.4 - 7.6 and 15% recovery rate.
2.Permeate flows for single element may vary ± 15%.
Element Dimension:

Model | Dimensions - Inches (mm) | ||
| A | B | C | |
MW-HF8040-375 | 40.0(1016) | 1.12 (28.5) | 7.9(201) |
MW-HF8040-400 | 40.0(1016) | 1.12 (28.5) | 7.9(201) |
MW-HF8040-440 | 40.0(1016) | 1.12 (28.5) | 7.9(201) |
Operating Conditions
Maximum Operating Temperature | 45℃(113℉) |
Maximum Operating Pressure | 1000psi(69bar) |
Maximum Pressure Drop (single element) | 15psi(1.0bar) |
pH Range for Continuous Operation | 3.0-10.0 |
pH Range for Cleaning | 2.0-12.0 |
Chlorine Tolerance | <0.1ppm |
Maximum Feed SDI15 | 5.0 |
Maximum Feed Flux | 17.0m3/h |
Operation Notes
1. Before installation please don't unpack the membrane elements, store in a dry and ventilated place away from light with temperature between 10 and 35℃. Elements should be handled with care when in transit.
2. Monitor water quality of pretreatment and discharge water in the first hour of the first use.
Our highly skilled craftsmen have devoted all their efforts to the creation of each of our Supplier of Vontron Ultra Low Pressure ULP-8040 Series Membrane at every step. The company introduces new high-tech products based on market demand, and provides customers with thoughtful service through market-oriented and customer-centric. No matter how many orders, no matter the process is complex or simple, we are always meticulous and strive for perfection to make every product well.
Hot Tags: 8040 high flux ro membrane elements, China, suppliers, manufacturers, custom, price, quotation, RO membrane elelments for sewage treatment, FRP tee cutting services, 8040 Seawater RO Membrane ELements, UV Resistant Marine GRE Pipe, FRP Papermaking Industry Tank, FRP RED ECC