We insist on determining the direction of enterprise development, developing superior membrane water treatment equipment, HF Reverse Osmosis Membrane GPD, Bitter Water System High Pressure GRE Pipe and providing first-class services from the needs of our customers and the public. We ensure the establishment of quality objectives, conduct management reviews, and ensure the availability of resources. We will be recognized as a leading brand for our innovative and leading-edge processes, trusted quality strength, and active social responsibility. We uphold the technology-led technology concept, through process changes, the introduction of advanced technology and equipment, from the raw material intake, production process, finished product inspection to form a whole process of the flow of work delivery system.
Applications
Desalination with high salt concentration, Production of drinking water and softened water for low-pressure boiler.
Technical Parameters
Model | Permeate Flow GPD (m3/d) | Active Membrane Area ft2 (m2) | Stabilized Salt Rejection | Feed Spacer mil (mm) | Test Conditions |
MW-HR4040 | 2500(9.5) | 85(7.9) | 99.5% | 28(0.7) | 225psi/2000ppmNaCl |
1. All performance data are collected at 25℃ (77℉), PH7.4 - 7.6 and 15% recovery rate.
2.Permeate flows for single element may vary ± 15%.
Operating Conditions
Maximum Operating Temperature | 45℃(113℉) |
Maximum Operating Pressure | 600psi(41bar) |
Maximum Pressure Drop (single element) | 15psi(1.0bar) |
pH Range for Continuous Operation | 3.0-10.0 |
pH Range for Cleaning | 1.0-13.0 |
Chlorine Tolerance | <0.1ppm |
Maximum Feed SDI15 | 5.0 |
Maximum Feed Flux | 17.0m3/h |
Operation Notes
If system shutdown short-term (within 15 days), please close valve of the system to keep membrane elements moist and wash regularly.
Package and Transportation
The packing materials are mainly vacuum bags, foam and cartons to prevent damage in transit. Keep the storage place cool and dry without direct sunlight, keep at low temperature. In the process of transportation, avoid direct sunlight and rain, handle with care. Membrane elements should be stored in their original packaging as far as possible before use. Please follow the instructions for membrane elements.
Certificate


Our solutions are widely recognized and trusted by consumers and will meet up with constantly developing financial and social requires for RO Membranes 8040/4040 Reverse Osmosis Water Spare Parts for RO System. We insist on people-oriented, system management, professional services, and are committed to the common promotion of corporate value and staff value. The management philosophy is the concrete embodiment of the corporate vision, mission and core values in the management.
Hot Tags: 4040 high rejection ro membrane elements, China, suppliers, manufacturers, custom, price, quotation, plain end FRP water pipe, Agriculture Used Container, membrane elelments high removal rate, Higher stiffness FRP pipe, Fiberglass Pipe Frp, FRP Smelting Industry Tank