Product Features
High rejection while High flux.
Applications
Desalination of seawater and brackish water, Concentration and Recycling of high salt concentration.
Technical Parameters
Model | Permeate Flow GPD (m3/d) | Active Membrane Area ft2 (m2) | Stabilized Salt Rejection | Feed Spacer mil (mm) | Test Conditions |
MW-HF8040-375 | 9000(34.1) | 375(34.9) | 99.5% | 28(0.7) | 225psi/2000ppmNaCl |
MW-HF8040-400 | 10200(38.6) | 400(37.2) | 99.5% | 28(0.7) | 225psi/2000ppmNaCl |
MW-HF8040-440 | 12000(45.4) | 440(38.1) | 99.5% | 28(0.7) | 225psi/2000ppmNaCl |
1.All performance data are collected at 25℃ (77℉), PH7.4 - 7.6 and 15% recovery rate.
2.Permeate flows for single element may vary ± 15%.
Element Dimension:

Model | Dimensions - Inches (mm) | ||
| A | B | C | |
MW-HF8040-375 | 40.0(1016) | 1.12 (28.5) | 7.9(201) |
MW-HF8040-400 | 40.0(1016) | 1.12 (28.5) | 7.9(201) |
MW-HF8040-440 | 40.0(1016) | 1.12 (28.5) | 7.9(201) |
Operating Conditions
Maximum Operating Temperature | 45℃(113℉) |
Maximum Operating Pressure | 1000psi(69bar) |
Maximum Pressure Drop (single element) | 15psi(1.0bar) |
pH Range for Continuous Operation | 3.0-10.0 |
pH Range for Cleaning | 2.0-12.0 |
Chlorine Tolerance | <0.1ppm |
Maximum Feed SDI15 | 5.0 |
Maximum Feed Flux | 17.0m3/h |
Operation Notes
1. Before installation please don't unpack the membrane elements, store in a dry and ventilated place away from light with temperature between 10 and 35℃. Elements should be handled with care when in transit.
2. Monitor water quality of pretreatment and discharge water in the first hour of the first use.
Hot Tags: 8040 high flux ro membrane elements, China, suppliers, manufacturers, custom, price, quotation, HR membrane filter, XR membrane water treatment purifier, ULP membrane economical and energy efficient, RO membrane manufacture for water treatment, XR Spiral Wound RO Membrane ELements, XR membrane reduce TOC